Description
Mobile, precise and fast recording of vital signs
Riester’s ri-vital spot check monitor is designed for the mobile, precise and fast recording of vital signs data at clinics, hospitals and outpatient treatments. ri-vital simultaneously measures NIBP, SpO2 and temperature (optional) and is clinically validated for adults and newborns weighing as little as 1 kg (2.21 lb).
- Coloured 4.3“ TFT display (SYS, DIA, MAP, pulse, SpO2, Temp, plethysmogram)
- Temperature alternatively with infrared technology for the ear measurement or with Filac™3000 for the oral/rectal measurement including probe dispenser.
- Memory function for measurement readings and infrared interface for thermo printer
- Shock resistant
- NIBP with mode for adults and neonates.
- Washable and disinfectable cuffs with coiled tube, extendible up to 2 m. Including cuffs for adults and large adults.
- SpO2 sensors with a cable length of 1.2 m (47.2 in) or optional 2.40 m (94.5 in)
Optional with PEARL measuring technology for the use with critical patients (e. g. neonates)
- Easy handling via membrane keyboard (disinfectable) and self-explanatory menu
- Practical storage facilities for accessories (cuffs, sensors, cable, probe covers)
- Efficient and lightweight rechargeable Li-ion battery pack (approx. 250 measurements)
- Portable version or mounted on a stable and smooth running mobile stand with large basket and optional printer holder
- 2 year warranty
Options
- External wireless printer
- Filac™ 3000 predictive oral/rectal thermometer
- Ear thermometer
- Mobile stand
- Full range of blood pressure cuffs and SpO2 sensors
Pulseoximeter
- Measurement range SpO2: 0..100% SpO2
- Display range: 0..99% SpO2
- Accuracy: Adults +/-2% (70-100%)
Children +/-3% (70-100%) - Pulse measurement range: 30..250 min-1
- Accuracy: +/-1%
Blood pressure
- Measurement range (adult): 2..280 mmHg (Systole)
15..260 mmHg (MAP)
10..220 mmHg (Diastole)
- Measurement range (neonate): 20..155 mmHg (Systole)
10..130 mmHg (MAP)
5..110 mmHg (Diastole)
- Overpressure protection: 300 mmHg
Other
- Independent protection system against excess pressure acc. to EN1060-3
- Measurement accuracy acc. to EN1060-4:2005
- Deviationfrom average value < 5 mmHg
Device
- Mains 115/230 V, 50/60 Hz
- Battery ri-accu® L, 7.4 V, Li-ion battery
- Operation time approx. 250 measurements NIBP and SpO2
- Charging time 8 hours
- Mains Adapter AC/DC Adapter plug, 100 V – 240 V
- Display illuminated LCD
- Dimensions
- with thermometer L 246 mm x W 167 mm x H 232 mm (L 9.69 in x W 6.58 in x H 9.13 in)
- without thermometer L 203 mm x W 167 mm x H 232 mm (L 7.99 in x W 6.58 in x H 9.13 in)
- Weight
- with thermometer 1,650 g (3.64 lb)
- without thermometer 1,500 g (3.31 lb)
- Casing PC and ABS
Reviews
There are no reviews yet.